Products
Primary Flow Signal
- Venturi Flow Meters
- Wedgetype Flow Meters
- Orifice Flow Elements
- PTC 6|Nozzle Flow Meters
- Specialty Flow Meters
PFS HVT Fabricated Venturi Flow Meter (HVT-FV)
0.50% Uncalibrated Uncertainty
Low Loss, Municipal & Industrial Applications
Line Size: 1/2 to 144 inches
Head Loss % of Differential: 3.50 to 10.0 percent
Recommended Pipe Reynolds Number: Greater than 75,000
PFS Cast Iron/Ductile Iron Venturi Flow Meters (HVT-CI,HVT-DI)
0.50% Uncalibrated Uncertainty
Low Loss, Municipal & Industrial Applications
Line Size: 4 to 96 inches
Head Loss % of Differential: 3.50 to 10.0 percent
Recommended Pipe Reynolds Number: Greater than 75,000 for basic accuracy
PFS Fabricated/Plastic Insert Venturi (HVT-FI, HVT-PI)
0.50% Uncalibrated Uncertainty
Low Loss, Internal / Flange Mounted
Line Size: 3 to 144 inches
Head Loss % of Accuracy: 3.50 to 10.0 percent
Recommended Pipe Reynolds Number: Greater than 75,000 for basic accuracy
PFS Rate of Flow Controller (HVT-FC)
0.50% Uncalibrated Uncertainty
Low Loss, Control Flow Rate
Line Size: 4 to 96 inches
Head Loss % of Differential (Venturi): 3.50 to 10.0 percent
Recommended Pipe Reynolds Number: Greater than 75,000 for basic accuracy
PFS Sealed Meter System (HVT-SMS)
0.50% Uncalibrated Uncertainty
Low Loss, Highly Contaminated Fluid
Line Sizes: 6 to 14 inches for 2 inch SMS; 16 to 96 inches for 3 inch SMS
Head Loss % of Differential (Venturi): 3.50 to 10.0 percent
Recommended Pipe Reynolds Number: Greater than 75,000 for basic accuracy
PFS Classical Venturi (CV)
1.00% to 1.50% Uncalibrated Uncertainty
Clean Liquids, Gases
Line Size: 2 to 48 inches
Head Loss % of Differential: 10 to 25 percent
Recommended Pipe Reynolds Number: Greater than 200,000 for basic accuracy. Consult PFS for lower Reynolds use.
PFS Rectangular Venturi Meter (HVT-RV)
0.75% Uncalibrated Uncertainty
Low Loss, For Rectangular Conduits
Line Size: 1/2 to 96 inches. Larger sizes available.
Head Loss % of Differential: 5.0 to 12.0 percent
Recommended Pipe Reynolds Number: Greater than 75,000 for basic accuracy
PFS Wedgetype Flow Meter (WM)
4.00% Uncalibrated Uncertainty
Dirty Liquids, Slurries
Line Size: 1/2 to 30 inches
Head Loss % of Differential: 25 to 60 percent
Recommended Pipe Reynolds Number: Must be greater than 500 for basic accuracy
PFS Wedge-X Flow Meter (WX)
4.00% Uncalibrated Uncertainty
Integral Manifold, Replaceable Wedge
Line Size: 2 inches
Head Loss % of Differential: 25 to 60 percent
Recommended Pipe Reynolds Number: Must be greater than 5000 for basic accuracy
PFS Orifice Meter Runs
0.5 to 0.75% Uncalibrated Uncertainty
Liquids and Gases, Pipe Spools Included
Honing available
Meets ISO, AGA, ASME, API requirements
Supplied with any combination of NDE required
PFS ASME PTC-6 Flow Nozzle
0.25% Always Calibrated
Highest Accuracy / Repeatability
Line size: 4 to 28 inches
Head loss (permanent pressure loss) in % of Differential: 60% to 85% (18% to 25% with optional outlet diffuser cone), Beta Dependent
Recommended Application, THROAT Reynolds Number: Greater than 500,000
PFS ASME Long Radius Flow Nozzle
2.00% Uncalibrated Uncertainty
Liquids and Gases, High-Velocity Flow
Line size: 2 to 24 inches
Head loss % of Differential: 30 to 85 percent, Beta Dependent
Recommended Pipe Reynolds number: Greater than 10,000 for basic accuracy
PFS ASME PTC 19.5 Throat Tap Flow Nozzle
0.70% Uncalibrated Uncertainty
High Accuracy
Line Size: 4 to 28 inches
Head Loss (permanent pressure loss) in % of Differential: 60% to 85% (18% to 25% with optional outlet diffuser cone), Beta Dependent
Recommended Application, THROAT Reynolds Number: Greater than 500,000 for basic accuracy
PFS ISA 1932 Flow Nozzle
0.80% to 1.20% Uncalibrated Uncertainty
Liquids and Gases, Lower uncertainty
Line size: 2 to 20 inches
Head Loss % of Differential: 30 to 85, Beta Dependent
Recommended Minimum Pipe Reynolds Number: Must be greater than 20,000 for basic accuracy
PFS Venturi Nozzle
1.21% to 1.74% Uncalibrated Uncertainty
Liquids and Gases, Lower Loss
Line size: 2.5 to 20 inches
Head loss (permanent pressure loss) in % of Differential: 5% to 20%
Recommended Pipe Reynolds Number: Greater than 150,000 for basic accuracy
- 1
- 2